{"id":43286,"date":"2024-04-26T23:10:57","date_gmt":"2024-04-26T23:10:57","guid":{"rendered":"http:\/\/localhost\/branding\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/"},"modified":"2024-04-26T23:10:57","modified_gmt":"2024-04-26T23:10:57","slug":"nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop","status":"publish","type":"post","link":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/","title":{"rendered":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP)"},"content":{"rendered":"<p>Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer (SOP)<\/p>\n<p>Students Name<\/p>\n<p>Institution Affiliation<\/p>\n<p>Purpose:<\/p>\n<p>The purpose of this procedure is to ensure all necessary instructions\/steps are taken for a safe and environmentally friendly, Nitrogen purging of the Agilent caret 5000 UV-Vis NIR spectrometry, without compromising the high standards of the eventual output. These instructions are meant to ensure: health of the operators is not put at any risk and that they have adequate knowledge to undertake the process; procedures go on in a systematic manner without failures. <\/p>\n<p>Scope of this SOP:<\/p>\n<p>The scope of this Sop covers the Nitrogen purging of the Agilent caret 5000 UV-Vis NIR spectrometry Explicit equipment levels, rules, method declarations shall be established before the work being undertaken. These shall comprise the Scope of Work.<\/p>\n<p>References:<\/p>\n<p>Procedure:<\/p>\n<p>A) Operator<\/p>\n<p>-Production supervisor-Selects the equipment to be used and reviews the methods to be deployed.<\/p>\n<p>-Fabrication Operator- Assembles all apparatus, materials (gases) and equipment, having tested them respectively. Should ensure perforated trays are well placed and all set-ups are perfect.<\/p>\n<p>b) OH&amp;S Information<\/p>\n<p>-The operator(s) of the purge process should be in protective clothing, sober mind and completely masked from the contact with possible electromagnetic radiations. They should be trained to be able to procure first aid services<\/p>\n<p>&#8211; Procedure should be done in a spacious environment with a first aid kit strategically placed. A well labeled emergency exit and trash bin should be in place <\/p>\n<p>c) Equipment and Materials:<\/p>\n<p>Precaution: Nitrogen should never be flushed without valves. All cylinders must have air tight valves.<\/p>\n<p>Plastic, Supply tubing (to direct the nitrogen jet)<\/p>\n<p>Pressure regulator and gauge (pressure to be maintained between 83-172kPA)<\/p>\n<p>Gas manifold (Fitted with regulators)<\/p>\n<p>Agilent Cary 5000 UV-Vis NIR spectrophotometer<\/p>\n<p>Sample compartment<\/p>\n<p>Heat exchanger (heat regulation)<\/p>\n<p>Flow Meters<\/p>\n<p>Screw drivers(to undo the plates and panels<\/p>\n<p>Ultra-pure liquefied  Nitrogen  (5.0)<\/p>\n<p>Instructions<\/p>\n<p>Make sure all environmental hazards are checked, and precautions highlighted herein  are taken into consideration.<\/p>\n<p>Ensure the Nitrogen purge system is set up to ensure constant nitrogen supply<\/p>\n<p>Fit the extended compartment to the spectrophotometer.(note  the spectrophotometer  should not be connected to a mains power source)<\/p>\n<p>Connect the tubing from the nitrogen purge system underneath the inlet tubes of the extended sample compartment.<\/p>\n<p>Open the nitrogen control valve to flush the Nitrogen at a supply pressure of  between 83-172kPA<\/p>\n<p>Adjust the array of flow meters ensure optimum circulation conditions are met.<\/p>\n<p>Instrument:0-20 l\/min<\/p>\n<p>Sample compartment:0-10 l\/min<\/p>\n<p>Allow the Nitrogen purging to run for 20minutes the close the nitrogen supply control valve<\/p>\n<p>Check the extend of purging by doing an oxygen scan and water vapor at the U.V-vis  region and  NIR region respectively<\/p>\n<p>Once satisfied with the  extend, detach   the sample compartment from the nitrogen supply system <\/p>\n<p>Remove  the base  of the  sample compartment from the spectrophotometer <\/p>\n<p>Realign the optics with respect to the floor of the spectrophotometer<\/p>\n<p>For safe removal of the base please ensure you:<\/p>\n<p>Remove the front door<\/p>\n<p>Remove the cover plate between the horizontal extrusion (unscrew the two screws at its  base) and floor<\/p>\n<p>Remove the lower plate<\/p>\n<p>Undo the fasteners holding the sample compartments floor and remove it.<\/p>\n<p>e) The production operator notes all parameters measured (water favor levels, oxygen levels, optics alignments) and along with other documents and       forwards them to the supervisor.<\/p>\n<p>    f) The supervisor inspects the work done and signs relevant logs, records and audit sheets.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer (SOP) Students Name Institution Affiliation Purpose: The purpose of this<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-43286","post","type-post","status-publish","format-standard","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter\" \/>\n<meta property=\"og:description\" content=\"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer (SOP) Students Name Institution Affiliation Purpose: The purpose of this\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/\" \/>\n<meta property=\"og:site_name\" content=\"sheilathewriter\" \/>\n<meta property=\"article:published_time\" content=\"2024-04-26T23:10:57+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/\",\"url\":\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/\",\"name\":\"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter\",\"isPartOf\":{\"@id\":\"https:\/\/sheilathewriter.com\/blog\/#website\"},\"datePublished\":\"2024-04-26T23:10:57+00:00\",\"author\":{\"@id\":\"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/f5844d28db4a1882523a0a69560bf0ab\"},\"breadcrumb\":{\"@id\":\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sheilathewriter.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sheilathewriter.com\/blog\/#website\",\"url\":\"https:\/\/sheilathewriter.com\/blog\/\",\"name\":\"sheilathewriter\",\"description\":\"Custom essay writing\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sheilathewriter.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/f5844d28db4a1882523a0a69560bf0ab\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/9cf817440d627e98709fcac9c5cc379958985e679d683af80df1879b5a471013?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/9cf817440d627e98709fcac9c5cc379958985e679d683af80df1879b5a471013?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\/\/opskill.com\/propapers\"],\"url\":\"https:\/\/sheilathewriter.com\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/","og_locale":"en_US","og_type":"article","og_title":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter","og_description":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer (SOP) Students Name Institution Affiliation Purpose: The purpose of this","og_url":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/","og_site_name":"sheilathewriter","article_published_time":"2024-04-26T23:10:57+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/","url":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/","name":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP) - sheilathewriter","isPartOf":{"@id":"https:\/\/sheilathewriter.com\/blog\/#website"},"datePublished":"2024-04-26T23:10:57+00:00","author":{"@id":"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/f5844d28db4a1882523a0a69560bf0ab"},"breadcrumb":{"@id":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sheilathewriter.com\/blog\/nitrogen-purging-of-the-agilent-carey-5000-uv-vis-nir-spectrophotometersop\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sheilathewriter.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Nitrogen Purging of the Agilent Carey 5000 UV-Vis NIR Spectrophotometer(SOP)"}]},{"@type":"WebSite","@id":"https:\/\/sheilathewriter.com\/blog\/#website","url":"https:\/\/sheilathewriter.com\/blog\/","name":"sheilathewriter","description":"Custom essay writing","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sheilathewriter.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/f5844d28db4a1882523a0a69560bf0ab","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/sheilathewriter.com\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9cf817440d627e98709fcac9c5cc379958985e679d683af80df1879b5a471013?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9cf817440d627e98709fcac9c5cc379958985e679d683af80df1879b5a471013?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/opskill.com\/propapers"],"url":"https:\/\/sheilathewriter.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/posts\/43286","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/comments?post=43286"}],"version-history":[{"count":0,"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/posts\/43286\/revisions"}],"wp:attachment":[{"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/media?parent=43286"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/categories?post=43286"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sheilathewriter.com\/blog\/wp-json\/wp\/v2\/tags?post=43286"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}